Load sensor
Load sensor SAHX-120B |
Output signal |
Accurency
|
Range scope |
Working temperature(℃) |
|
- 0.5-4.5V/CAN/RS485 |
±2%(F.S) |
0-120℃ |
-40~ 70 |
Load sensor |
Output style |
linear error(%) |
Working temperature(℃) |
|
- No load/full load/overload |
±5 |
-20~ 85 |
-Continuous analog quantity |
±5 |
-20~ 85 |
It can detect the no-load, full load, overload and partial load state of the muck car, mud truck, coal truck, ore car and other cars.
Position sensor/lift sensor |
Model |
Principle |
Contact form |
output method |
Power supply type |
action distance(mm) |
|
P119 |
Reed switch principle |
Normally open/normally closed optional |
ON/OFF switch signal high and low level |
24V DC以下 |
Power supply 39-41 (iron plate) 83-85 (non-iron plate parallel test) |
SPH119 |
Hall principle |
/ |
0~5V |
9~28 VDC |
non-iron plate parallel test 0~25mm |
Airtight sensor SP1191 series |
Model |
Supply voltage |
Contact form |
trigger distance |
output method |
Operating temperature range |
action distance |
trigger method |
|
SP1191-A |
12~30 VDC |
|
≤15mm (face to face trigger) |
No trigger, output 5V, green light is always on When triggered, the output is 2.5V, and the green light is dim The thread is cut, the output is 0V, and the light is off |
-30~+120℃ |
≤100mm (Parallel movement after face-to-face trigger) |
magnet trigger |
SP1191-B |
12~24 VDC |
Type A contact (normally open) |
≥20mm |
Switch When triggered, turn on No trigger, disconnected |
-25~+80℃ |
|
magnet trigger |
SP1191-C |
|
Form A contact (normally open) |
|
High and low level output Trigger (when airtight): high level light is on Leave (when open): low level light off |
-25~+80℃ |
|
|
It can detect the lifting and lifting of dump truck, muck truck, dump truck, garbage truck bucket and car.
Positive and reverse tachometric transducer
Positive and reverse tachometric transducer SPH3A0-10B-V-MEP10 |
output mode |
Supply voltage |
Detector detection distance(mm) |
working environment |
|
Open-collector output |
DC 5V~24V
|
5-10 |
Temperature-20~80℃ Humidity≤90% |
Temperature and humidity measurement
ST116/117 Analog signal temperature sensor |
Supply voltage
|
Measuring range
|
Accuracy of detection |
Output signal
|
Housing |
|
3.0~5.5 VDC
|
-40 ℃ ~ +85 ℃ |
|
linear voltage :0℃-500mV,10mV/℃ |
Stainless steel 316 |
±0.5℃(-10~+85℃) |
Single bus data communication |
Widely used in cold chain logistics transportation, agriculture, forestry, meteorological environment, greenhouse, laboratory, Internet of things system and other industries as well as climate room, warehouse
Storage, ship, dock, flower cultivation, pharmacy, supermarket warehouse, museum, fog spray intelligent control system and other places.
T119 Temperature Sensor |
Supply voltage
|
Measuring range
|
Accuracy |
Output signal
|
Protecion Grade |
|
5 VDC
|
-40 ℃ ~ +80 ℃ |
|
Modbus RS485 |
IP67 |
ST118 Temperature and humidity sensor |
Supply voltage |
Measuring range |
Output signal |
Housing |
|
5 VDC(Current≤15mA) |
Temperature:±0.2℃(0~+60℃) Humidity:2%(25℃) |
RS485(MODBUS) |
Flame retardant engineering plastics UL94-V0 |
oil measurement sensor
Reed tube type oil level sensor |
output mode |
input/output range |
Outgoing way |
Installation methods |
Material |
Action point spacing |
measurement accuracy |
Range scope |
Float |
Working temperature |
|
Resistive output (no transmitter) |
input:no output:KΩ |
Second line out (A junction box can be added) |
Thread, flange |
SUS304 SUS316 |
5mm-10mm |
±5mm ±10mm |
0.1m-1m |
NBR Float |
-40℃~+85℃ |
Voltage output (with transmitter) |
input range:12V(24V) output range:0-5V(1-10V) error range:0.3V |
Three line out (A junction box can be added) |
Current output 4-20mA (with transmitter) |
input:24V output:4-20mA |
Add a junction box for three wires |
Fuel consumption meter HOCM03 |
Accuracy of measurement |
Flow range |
Working temperature |
Product material |
Working voltage |
Digital output (one can be selected) |
Oil circuit interface |
|
±1% |
10-450 L/H |
-20℃~80℃ |
aluminum |
24V DC |
RS232 interface (1 way) RS485 interface (1 way) |
M14*1.5 |